
Active
Description
Small hydroelectric power plant, manufacturer AC-TEC GmbH Kaltern (South Tyrol/Italy), serial number SN-29-2011 (year of construction 2011) Fully functional. Condition needed. Functionality tested before decommissioning. Optical condition very good. No damage. No signs of wear. Scope: Pelton turbine, shut-off system with motor drive, low voltage switchgear Space requirements: (b*h*t) 2000 x 1100 x 1000 mm Pelton turbine with single nozzle Qa=5.8l/s Hnetto at Qa=95m Efficiency etaT=84% and etaG=about 87% Pelectral approx. 4kW Electrical nozzle needle adjustment Impeller arrangement vertical Housing, nozzle needle, nozzle, chrome steel inlet nozzle Pelton impeller: Impeller hubs and shovels of chrome steel Blades from the full milled, blades individually replaceable 100% reproducible Three-phase asynchronous generator: 5,5kW n=1020U/min Effect-optimized execution Protection class IP55 Manufacturer: VEM 24 VDC engine-driven shut-off system for discharge of spring water in the event of failure of the UPS system Flange flap DN 100 Body GGG, stainless steel disc Low voltage switchgear for small hydroelectric power plant as a wall switch cabinet made of steel sheet Total size (b*h*t) 600x800x300 mm With control cabinet lighting With door contact switch With control cabinet heating with operating socket and automatic fuse with schematic pocket with assembly rail system or wiring for power and control potentials Installations: Power supply for switchgear rated current up to 25 A Inlet terminals according to the line cross section Main switch with manual operation Control voltage supply 230V AC (without control transformer) incl. control fuses with auxiliary contacts Control voltage supply 24V DC with power supply 230VAC / 24 VDC (160 VA) incl. battery system and control fuses with auxiliary contacts Auxiliary relays for general control linkages Lamp test device for all tell-tale lamps Disruption acknowledgement Drives: Drain valve Feed valve Equipment of the drive with: Short circuit and overload protection Motor protection switch Selector switch: Hand-0 car Reporting lamps: operation, malfunction Turbine control for energy return Flow valve Actors: 2 solenoid valves Sensors: Limit switches Automation for all drives, sensors and actuators included in telecontrol technology. EMSR documentation consisting of: circuit diagram & nbsp; Structure drawings of the control cabinets
Categories
⚡Energy & HVACAC-TEC
Small hydroelectric power plant, manufacturer AC-TEC GmbH Kaltern, serial number SN-29-2011
Small hydroelectric power plant by AC-TEC GmbH Kaltern, SN-29-2011 (2011), fully functional, Pelton turbine Qa=5.8l/s Hnetto=95m etaT=82%, dimensions 2000x1100x1000 mm.
Current Bid
8.000 €
Price checked 26/09/2026, 13:41:40
Lot ends in
19d 15h 18mLot Details
- Currency
- EUR
- Location
- Staudach-Egerndach, DE
- Lot Ends
- 16 Oct 2026, 07:51:00
- Auction Ends
- 16 Oct 2026, 07:51:00
- Auction Started
- 15 Sept 2026
- Lots in Auction
- 1
